*RMC12003 - 08/18/2006 - The Online Queue Reorganization has been * updated to use the R#OR start methods that * can notify printers that are not terminal * attached tasks/devices such as JESP, LPRD, or * SMTP printer. * * THIS FIX IS RELEASED CONCURRENTLY WITH RMC12004 * *Problem Summary: * The program was not updated when the new SIGNAL= parameter was * added to the ROPES Device Control Block definition. As a result, * the printer being affected by the report being processed cannot * be sent the Status Modified message. The R#O1 task abends with * abend code RODB. * *Symptoms: * The R#O1 task abends with RODB if R#OR is running and it tries * to signal a non-terminal oriented printer task. * *Temporary Fix: * The following replacement object modules must be obtained from * technical support: * ROPEQORG * ROPEQMSG * *Permanent Fix: * This problem will be corrected by PTF in the next release of * ROPES. * *End Of Document