*RMC17003 - 08/17/2011 - Several problems have been resolved and some 00010001 * enhancements have been made to the Batch Queue 00020001 * Reorganization program ROPEBQOR. 00030001 * 00031001 *Problem Summary: 00040001 * The Batch Queue Reorganization program does not purge reports with 00050001 * Discard Options 1, 2, and 7 due to incorrect addressing of the RPI 00060001 * record area. The storage used for the RPI record and the data 00070001 * area that mapped the record were not the same, so no reports 00080001 * appeared to be assigned to a printer. 00080101 * 00080201 * Message ROPES2128 has been enhanced to name the report in the RIB 00081001 * that does not have an RPI entry. 00082001 * 00083001 * Additional Snap Dumps and WTOs have been added for diagnostics 00084001 * when activated by ROPES Technical Support. Remote parameter lists 00085001 * were created for the SNAP macro for consistency with the rest of 00086001 * the code in the module. 00086101 * 00086201 * The listing data set (SYS006) was not closed correctly. 00087001 * 00088001 * The end of the internal report table was being overrun. 00089001 * 00089101 * The diagnostic Snap dumps require that the module be RMODE(24) 00089202 * and NORENT due to DCB restrictions. 00089302 * 00089402 *Symptoms: 00090001 * Discard Option 1, 2 and 7 were not being enforced. 00100001 * 00110001 * Message ROPES2128 does not indicate the report in error. 00111001 * 00112001 * SNAP dumps and WTOs tracing messages can now be activated with 00113001 * zaps provided by ROPES Technical Support when required. 00114001 * 00116001 * Errors after program termination may be reported for unclosed 00116101 * data sets. 00117001 * 00118001 * Message ROPES2128 could be issued in error. 00119001 * 00119101 *Temporary Fix: 00120001 * 00130001 * THIS FIX SUPERCEDES RMC17001 AND RMC17003 00140001 * 00150001 * The following replacement object modules must be obtained from 00160001 * technical support: 00170001 * ROPEBQOR 00180001 * 00190001 * The following replacement source modules must be obtained from 00191002 * technical support: 00192002 * LINKNORT, LINKRENT 00193002 * 00194002 *Permanent Fix: 00200001 * This problem will be corrected by PTF in the next release of 00210001 * ROPES. 00220001 * 00230001 *End Of Document 00240001